Specifications

SPECIFICATION VIEW

MODEL Titan Vista 9+1K(G) Titan Vista 9+1KS(G) * Titan Vista 9+2K(G) Titan Vista 9+2KS(G) * Titan Vista 9+3K(G) Titan Vista 9+3KS(G) * Titan Vista9+ 6K (G) Titan Vista 9+6KS(G) * Titan Vista 9+10K(G) Titan Vista 9+10KS(G) *
CAPACITY (KVA/W) 1KVA / 900W 2KVA / 1800W 3KVA / 2700W 6KVA / 5400W 10KVA/9000W
INPUT
INPUT VOLTAGE 200/208/220/230/240VAC
VOLTAGE RANGE 110 - 300VAC
FREQUENCY RANGE 40Hz - 70Hz 46 - 54Hz or 56 - 64Hz
PHASE Single Phase In / Single Phase Out
INPUT POWER FACTOR ? 0.99 @ nominal voltage (100% load)
OUTPUT
OUTPUT VOLTAGE 200/208/220/230/240VAC
OUTPUT POWER FACTOR 0.9
AC VOLTAGE REGULATION (Batt. Mode) ± 3% ± 1%
FREQUENCY RANGE (Synchronized Range) 47 - 53Hz or 57 - 63Hz 46 - 54Hz or 56 - 64Hz
CURRENT CREST RATIO 3 : 1
TOTAL HARMONIC DISTORTION ? 3% THD Linear Load ; ? 6% THD
Non-Linear Load
? 4% THD Linear Load ; ? 7% THD Non-Linear Load ? 3% THD Linear Load ; ? 6% THD Non-Linear Load
WAVEFORM Pure Sinewave
TRANSFER TIME (AC Mode to Batt. Mode) Zero
TRANSFER TIME (Inverter to Bypass) 4ms (Typical) Zero
OUTPUT SOCKET 2 x British Socket 4 x British Socket Hard-Wiring (Terminal Block)
BATTERY
SEALED LEAD ACID MAINTENANCE FREE
BATTERY - CSB/YUASA/PANASONIC Japan Battery
12V 7 AH x 3pcs Depending on the capacity of
External
Batteries
12V 7AH x 6pcs Depending on the capacity of
External
Batteries
12V 9AH x 6pcs Depending on
the capacity of
External
Batteries
12V 7AH x
20pcs
Depending on
the capacity of
External
Batteries
12V 9AH x
20pcs
Depending on
the capacity of
External
Batteries
BACKUP TIME (Depending on Load) 15 - 20 mins 15 - 20 mins 15 - 20 mins 15 - 20 mins 15 - 20 mins
RECHARGE TIME 4 Hrs. to 90% 4 Hrs. to 90% 4 Hrs. to 90% 7 Hrs. to 90% 9 Hrs. to 90%
CHARGING CURRENT (MAX) 1A 8A 1A 8A 1A 8A 1A 4A 1A 4A
STATUS INDICATION
LCD DISPLAY UPS Status, Load Level, Battery Level, Input / Output Voltage, Discharge Timer, UPS Fault
AUDIBLE ALARM Battery Mode, Low Battery, Overload, Fault
COMMUNICATION
POWER MANAGEMENT SOFTWARE Support Window Family, Linux, Sun Solaris, IBM Aix, Compaq True 64, FreeBSD, HP-UX, MAC
- Automatically Shut-down, Saves Application Data Before Exit
- Warning Notification Via E-Mail/Pager/Broadcast
- Power Flow Display for Monitoring UPS Status
- Remote Monitor/Control via LAN
- Schedules System Shutdown/Restart
- Safety Shutdown Multi System
INTERFACE RS 232 & USB Port
INTELLIGENT SLOT Optional SNMP/AS 400 Relay Card
EMERGENCY POWER OFF Yes
SURGE PROTECTION & FILTERING
SPIKE, SURGE & LIGHTNING PROTECTION Yes
OVERLOAD, SHORT CIRCUIT PROTECTION Yes
PHYSICAL
OPERATING ENVIRONMENT 0-40°C, 20 - 90% Relative Humidity (Non-Condensing)
NOISE LEVEL < 45dB @ 1 Meter < 58dB @ 1 Meter
DIMENSION (DxWxH)mm 397 x 145 x 220 421 x 190 x 318 592 x 250 x 576
WEIGHT (KG) 13 7 26 13 28 13 81 25 83 27
WARRANTY
UPS WARRANTY 3 Years Full Warranty Include Parts & Labour. 2 Years Warranty for Battery (*Not applicable for KS model)